Doc inlet temp during regen.

Oct 15, 2023 · CM871 High DOC temp during regen. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful ...

Doc inlet temp during regen. Things To Know About Doc inlet temp during regen.

DPF Temperature Sensor Module – A three-probe sensor where one probe tracks temperature levels at the DOC inlet, another monitors temperature at the DPF inlet, ...Exhaust Gas Temp 572, DOC Inlet Temp 572, DPF Outlet Gas Temp 1013 and still the REGEN process did not want to finish. The tech cleared my ash level to see if that would work and nothing. I got some recommended solutions, drop and burn the DPF / DOC, sensors, etc..during an engine bench test in this study. Based on the dropped to idle (DTI) test, a test method is developed to determine the safe regeneration temperature of the DPF. The results show that when the inlet temperature of the DOC is more than 240 C, the DOC begins ignition and reaches theMonitor smoke control status during regen. Smoke control status should be 0. DOC Inlet Temperature Sensor non-responsive Monitor DOC inlet temperature. No temperature change after engine startup indicates sensor problem. Intake Throttle Valve not functioning properly Listen for the ITV to sweep at key up. Turbo not functioning properly Perform ...Results show that at high DOC inlet temperatures (>190 °C), the DMDF mode combined with DOC achieves the high DPF inlet temperatures and the high NO 2 /PM ratio, which is benefit for passive regeneration. During active regeneration, the initial regeneration temperature, the fuel penalty and the emissions of PM, particulate number (PN), NO 2 ...

DOC face plugging, or DOC sulfur poisoning due to not using Ultra Low Sulfur Diesel (ULSD) fuel. Therefore, the AFI tip should be cleaned and the DOC inlet should be inspected before replacing the AFI. Follow the procedures in Guided Diagnostics to inspect and clean the DOC. Service Regeneration Once the soot level reaches 170%, the engine is ...DOC temp looks good but the DPF temp is too low. ... Dd15 does not go past 370 degrees during regen , ... It is in regen zone 2. I started regen. Regen started. DOC inlet go to 750 and both others are around 750 as …

Apr 10, 2018 · Still not temp. Have fault traced with G/D. Replaced egr valve. checked diff sensor,tubes,vgt lever,boost leaks,fuel pressure to A/T fuel doser and made sure it wasn't plugged. During regen the exh temps are (inlet 739) (after cat 969-978) (outlet 877-904) It goes back to idle and soot level reads the same and only code active is for soot level. Also, is the DOC and DPF due for cleaning? It sounds like you have access to Insite. When running a regen you need to open up data monitor and watch all the exhaust temps and doser injector state. Once a regen is initiated the DOC inlet and DPF inlet need to reach about 525 -550 degrees.

Check the diesel particulate filter (DPF) assembly and check for any exhaust leaks, cracks, signs of melting or excessive deposits. Check the diesel oxidation catalyst (DOC) filter assembly and check for any exhaust leaks. Check the exhaust brake valve for full functionality. Check for any excessive ash accumulation in the DPF filter assembly.Exhaust Gas Temp 572, DOC Inlet Temp 572, DPF Outlet Gas Temp 1013 and still the REGEN process did not want to finish. The tech cleared my ash level to see if that would work and nothing. I got some recommended solutions, drop and burn the DPF / DOC, sensors, etc..You can tell by watching your temperatures during a regen. If your DPF intake is lower then your DPF outlet, and theyre both above 800F, it's called 'inverted temps'which indicate your DOC ...more ...Monitor temperature rise across DOC during regen. Little or no temperature ... 4 SPN 3242/FMI 2 This diagnostic condition is typically DOC Inlet Temperature ...

The influence of far post injection in cylinder or downstream injection in the exhaust pipe on the DOC inlet temperature can be negligible (Chen, P. et al. (2014 ... Kim, Y. W., Van Nieuwstadt, M., Stewart, G., & Pekar, J. . Model Predictive Control of DOC Temperature during DPF Regeneration, SAE Technical Paper, No. 2014-01 ...

The T2 sensor, at the DOC outlet, provides feedbacks for closed loop controls. A fast response control system ensures the DOC outlet temperature stays on target while engine operations vary considerably. To verify the tight DPF inlet temperature control, an active regeneration was enabled during a NRTC test. The results are shown in Figure 8 ...

- During the high speed portion of the test, inlet NOx levels remain above 500 ppm, and outlet NOx levels are approximately 300 ppm as expected. - DTC P220E may be generated when this condition is observed. Replacement of the sensor returns values to the expected range: - If the above condition is present: • Replace the Inlet NOx SensorDOC inlet temperature; DPF inlet temperature; DPF outlet temperature; The MAXIMUM difference between the sensor readings should be 24 o C (43 o F). If the difference exceeds 24 o C (43 o F), replace the temperature sensor module assembly (the 3 temperature sensors are connected on the same CAN-BUS module and cannot be replaced separately, or …(11-12-2017, 04:56 AM) trs100 Wrote: (11-12-2017, 02:40 AM) am2000am Wrote: (11-11-2017, 08:49 PM) trs100 Wrote: Hi, Trying to perform parked regeneration on Cascadia with DD15, but when it reach temperature to turn the after treatment injector ON it stays off. All parameters look good only Fuel Doser Injection Status is 0. After treatment injector and …Mar 15, 2017 · DPF regeneration temperature rising strategy chiefly considers two temperatures including DOC inlet temperature and the DPF inlet temperature. Temperature rising approaches is based on Great Wall 4D83 diesel engine whose performance parameters are listed in Table 1 and DPF experiment system is shown in Fig. 8. Secondary post injection (Post ... Jan 11, 2020 · Force regen after having dpf filters cleaned and temps are as follows After treatment DPF outlet 1024 After treating DPF intake 1041 After treatment diesel oxidation catalyst temp 640 Is this normal 30min I to regen for catalyst to be so low? Any info appreciated Reply Dcmechanical Location Offline Senior Member Reputation: 396 Thanks Given: 952

DOC inlet temperature; DPF inlet temperature; DPF outlet temperature; The MAXIMUM difference between the sensor readings should be 24 o C (43 o F). If the difference exceeds 24 o C (43 o F), replace the temperature sensor module assembly (the 3 temperature sensors are connected on the same CAN-BUS module and cannot be replaced separately, or …- Observe exhaust gas temperatures from DOC Outlet Temp, DOC Inlet Temp and DPF Outlet Temp. - Refer to Aftertreatment Diagnostic Manual Supplement for information regarding OBFCT. 4. If OBFCT runs successfully, go to Step 7. 5. If OBFCT aborts, replay OBFCT using Service Maxx and observe Aftertreatment temperatures and diagnostic trouble codes. gmmerlin · #2 · Jun 23, 2007. NO, during the regen process, extra fuel is sent to the DOC (converter) which causes it to heat up. The hot exhaust gases from the DOC are sent to the DPF for the regen. So all the heat is going to be from the DOC back. There are EGT sensors pre and post DPF to monitor the temp.Catalyst (DOC), a chemical reaction occurs, and the exhaust system temperature increases to a level that oxidizes the soot in the filter. W2005917 Aftertreatment Fuel Injector (AFI) The Discharge Recirculation Valve (DRV), mounted on the charge air cooler inlet pipe, increases exhaust system temperature by recirculating air back into the ...Start looking at it, doc temps run up to 700 degrees within the first 5 minutes but I never see any pressure kick up from the Hydrocarbon doser. By 10 minute mark all temperatures holding steady around the 400-500 mark. Checked intake/exhaust leaks, intake throttle valve, egr valve, ensure all items are were they should be during the regen process.The addition of engine exhaust to intake air increases the over- all heat capacity of the charge, leading to a reduction of peak combustion temperature. Since ...There is always something . Excessive idling does cause the DPF to need a regen more often. The Pete I was in, it was recommended that if we had to idle due to temps, that we raise the idle to 1500 to help keep the DPF hot enough to regen itself. However, with the other issues you said it has, sounds like it needs to see Mr. Peterbilt.

During a proper regen, DOC inlet temp, or temp #1, should be about 550-600. DOC outlet temp, or temp #2, should be 1000-1200 degrees. DPF outlet temp should be 950 to 1200. In a healthy system, the engine injects fuel into the exhaust during a regen that the DOC burns to create the heat. The heat is used to BAKE down the collected soot …

During vehicle operation, active regeneration is performed when the accumulated soot and ash reach boundary limits. In this operation, the particulate soot is ...Jan 15, 2017 · During an active regen, engine exhaust temp is slightly higher than normal but not significantly. Maybe 50 to 100 deg. F at best. The high temps are in the exhaust NOX/DPF filter. Everything upstream of that is pretty much normal from my observations. See this video on an entire active regeneration. DPF inlet temperature: 550°C; Soot load: 4.1 g/dm3. It should be noted that there was almost no NO2 generation over the DOC during active regeneration. This ...The addition of engine exhaust to intake air increases the over- all heat capacity of the charge, leading to a reduction of peak combustion temperature. Since ...Pressure drop and temperature during active regeneration (500°C) DPF inlet temperature: 500°C; Soot load: 4.1 g/dm 3. ΔP C - DOC pressure drop; ΔP F - DPF pressure drop; F - Fuel flow rate T C1 - DOC inlet temperature; T C2 - DOC outlet temperature T F1 - DPF inlet temperature; T F2 - DPF outlet temperatureHere are some of the data I wrote down during the parked regen: DPF DIFFERENTIAL PRESSURE: 0.1hg AFTERTREATMENT FUEL PRESSURE: 14.4psi …Oct 15, 2023 · CM871 High DOC temp during regen. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful ... a. If the DOC inlet pressure starts out above 10 kPa (1.45 psi) and decreases during a parked regen, this indicates that the DPFs were plugged and the parked regen has cleared them. Go to step 8. b. If the DOC inlet pressure starts above the pressure specified below and stays high, the DOC is considered plugged. Go to step 9. Table 1. Emissions ...

After it stopped my truck requested another park regen. If you’re needing that many regens, you may need a new filter or perhaps a sensor. You should go see your truck manufacturer. I should add that 200° is normal temp for your dash to show. Mine goes up to about 225° before the fan kicks in and brings it back down to 200°.

Yellow (Solid or Flashing) to indicate the need to regenerate the Diesel Particulate Filter. ... Observe exhaust gas temperatures from DOC Inlet Temperature, DPF Inlet Temperature and DPF Outlet Temperature. ... perform 1 additional OBFCT. - Watch for temperatures to raise (please note that during high soot load levels the DOC and DPF ...

Introduction. During the thermal regeneration process of the diesel particulate filter (DPF), the exhaust temperature at the DPF inlet needs to be heated up to above 500 °C to oxidize the accumulated soot particles in an efficient way [1], [2], [3].Monitor DOC outlet temperature. Temperature should be greater than 100°C (212°F) prior to regen. A parked regeneration initiates and runs indefinitely. (Intake Throttle on Series …9 08-30-2020, 03:36 PM. (08-29-2020, 09:30 PM)Diesel Electronic Solutions Wrote: Hi we are the first ones in North America to develop a DD15 DPF emulator. The current version works for 2011-2013 trucks. The one for 2014+ trucks is still under development and should be released by next month.Was given log file from last completed regen on the truck 10 days earlier. Comparing the 2, boost pressure and doc inlet pressure is slightly lower throughout regen. dpf out temp reaches above 1200 but doc out temp is above 1000 as well. Will upload if someone wants to compareMonitor DOC inlet pressure and engine speed during the regen. Compare your DOC inlet pressure reading to the screen shots and descriptions below in (a and b) to determine what step to go to next. a. If the DOC inlet pressure starts out high above 10 kPa (1.45 psi) and decreases during the parked regen, this indicates the DPFs were plugged and ...Vehicle fails to regen. During High idle regen, DOC outlet max 479 F , Command boost pressure 0%, fuel doser inject ... DOC inlet temp doesn't go past 495 degrees. DOC stops around 515 and DPF temp is at 495. Checked for exhaust leaks = none f ...Volvo D13 regeneration. we have couple of trucks on our fleet with the same problem. The forced regen would start but runs indefinetly and not continuously. T he exhaust temp rises to about 500, dpf inlet and outlet reaches up to 920 and then engine suddenly changes tone, shuts of the aftertreatment injector, dpf inlet and outlet temps drop for ...During regen the exh temps are (inlet 739) (after cat 969-978) (outlet 877-904) It goes back to idle and soot level reads the same and only code active is for soot level. ... I would think if there was an issue with the DOC the inlet temp would be off and other temps as well. For example, if the DOC is face plugged the outlet temp usually ...validation parked regeneration as noted in the troubleshooting. Troubleshooting for the 3711/31 fault should be completed to verify there is not an actual component issue causing low DOC inlet temperature such as a drifted DOC inlet temperature sensor or a sticking front Jake solenoid. In active DPF systems, HCs are introduced into the exhaust gas (via engine post-injection or exhaust injection) and oxidized over the DOC in order to increase the DPF inlet temperature. This functionality is typically combined with NO 2 generation for passive DPF regeneration.

• Exhaust temperature drops between turbo and DOC/DPF Inlet. • Engine load is ... Enter Menu In The Digital Display Regen - REQUEST DIESEL PARTICUALTE FILTER ...Jan 23, 2018 · What are the temps showing when you are running the regen? Presuming you are using DDDL? You should see the dpf inlet, the catalyst, the outlet. You want the inlet to show 400, the filter inlet at 450 and above, and the outlet at 450 and above for when the doser will open up and start heating the catalyst up more. In many active DPF systems, the filter inlet temperature is raised to about 550°C during active DPF regeneration, which may produce even higher temperatures at the filter outlet, and at the tailpipe, due to the heat of combustion of the burned soot.Instagram:https://instagram. kansas texas basketball gamewho is ku football coachpsa announcement meaningiowa state kansas football tickets A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid. bill self bornbsn programs in kansas A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid.... inlet temperature sensor. Source: Cummins Quickserve. 2009 Cummins ISL Air Intake Overview ... DOC w/ DPF Emissions Control Systems Service. Exhaust, Intake and ... bill sef ... inlet temperature sensor. Source: Cummins Quickserve. 2009 Cummins ISL Air Intake Overview ... DOC w/ DPF Emissions Control Systems Service. Exhaust, Intake and ...The step response of DOC- out temperature can be acquired by injecting constant amount (i.e. 50 mg/s) of Diesel fuel into the exhaust pipe upstream of the DOC during different steady states (i.e. constant inlet temperature and mass flow rate of exhaust gas).